TECHNICAL SPECIFICATIONS
SBR & EPDM & ROLL BLOCK ANTI-STATIC AND HYGIENIC
FLOOR MATERIALS
TECHNICAL FEATURES
Products are patented and registered design. (Locked and blocks pasted to the floor because the weight of the block and nails with products to each other through the deadlocks; floor, provides great importance in terms of product and usage)
Products. TS EN 1176-1 \ 15.4.1999 and TS EN 1177 \ 15.4.2002 / TS 4857-1 \ EN 1817 \ 23.01.2001 standards and features antistatic.
Our products have CE standard document.
Products ISO 9001, ISO 14001, OHSAS 18001 quality standards and safety certificates.
Our products are suitable for recycling.
Our products smell and hygienic.
RUBBER FLOOR MATERIALS
PRODUCT FEATURES
TECHNICAL SPECIFICATION
Chemical analysis (01,1.5 / 2) completely stripped of metal wire and harmful substances 1. quality pellets, 5Dow%, 4% elastic Epoxy, 4% debt / stainless grinding powder, 2% carbon fiber / %2 carborundum % 5demir oxide paint was found and anti-static products, indicating that the same standards and production was done in order to prove at least 2 separate reports and testing procedures in the university should be taken.
During the floor slab coupling products, coatings, weight and volume to constitute at least should be in blocks 70x100/300x120
All products, especially links between blocks and blocks founding anchors, locks or quotation system must have.
M2 weights of the products used shape and design according to the average (-, + 1/4Kgr) to be requirement (19.5 Kgr thickness 2cm, 3cm thickness 25 Kgr, 4cm thickness is about 34/39 Kgr density and thickness according to the weight of m2 test final report must be available. M2 weights of the products used according to the average shape and design
Serrated non-slip stairs composite / metal / surface and can be used in heavy pedestrian traffic and parking areas approved 45/55 (SHORE (A) the university should have a smoothness test report.
Between the manufacturer's products, especially in children's play areas and nursery furnishings applied to the sides of rubber blocks the effect of impact and injury preventive use of university-approved anti-static rubber blocks and borders must have a water trough
All products in the EU standards (as approved stating that use of open spaces) is valid internationally accredited Ce document should have.
The manufacturer of the product
or production company's international
authority and the validity of the
application will be presented,
including at least 2 times control
has been ISO 9001, ISO 4001, OHSAS
18001 certificate must have
Producers or production companies
and products authorized all of
the products also can be read clearly
the pressure was specified with
brand and design must be registered
and the registration of this design
for decades used familiar shapes
(triangle, quadrangle, pentagon,
hexagon, star, key stone, single
pazzle, etc., Shape of the must
be original designs should be
Critical
fall height of 270 cm HIC test
results in accordance with the
criteria report stating that
the university should.
Stating
that in accordance with DIN standard
4102-11998-05 combustion test
report must have
Electrical
resistance values with the University
report TS / EN standards must
conform to the (395 kohm)
TSE
1176-1177 / document must have.
Anti-static
values and land vertically transition
resistance is below 10 to the 10
OHM’un report stating that
the university should be, (particularly
children at the time of play
and friction arising from static
electricity to prevent electric
shock)
16.TS
EN 1081 ICS 83 060 standard products
according to the anti-static
chemical substances (carbon,
karbonandum, etc.) was found
in the report pursuant to this
report indicates, and resistivity
values and 10 to the $ 13 OHM
0001 OHM/ M University report
that indicates the range should
be.
All
products Anti-static (TS 2734
and TS EN 1081 standards (vertical
resistor 2600, the soil resistance
to 20.000, the surface resistance
of 5000 K OHM) Current MA 0384
vertical resistance, soil resistance
at 0.05, the surface resistance
at 0.2 K OHM compliance test
report as a must have.
TS
EN 1081 ICS 83 060 According
to the standard electrical resistance,
electrical breakdown strength
up to 789 volts / cm as the standard
test report stating that EN should
be
Water-absorbing
composite surface / ramp 60893-2
Article 8.2 mg should be.
TS
EN 661 and similar to water absorption
and non-flame against sudden
temperature and flame spread
properties Determination of the
positive test reports must be
available on the university
Abrasion
(TS 659/EN660-1/EN 660-2) positive
test report must have.
Cash
/ rupture ISO 2285 / 2001 E standards
must have a positive test reports.
Swallowing
sound transmission loss of acoustical
test according to ISO 10534-2
standard, the application of
noise and vibration absorption
in the ground with a standard
insulation test and positive
reports should be.
TS
11900 EN 1399 According to the
standard rubber blocks and the
burning cigarette is extinguished
on the floor, etc.. against heat
and flame resistance in accordance
with standard specifies the test
report stating that the university
should have a positive
(ISO
10534-2) standard according to
the Sound absorption loss, depending
on frequency 800-0.04, sound
transmission loss frequency depending
on the 3000/25 average of measurements
db, (50-6400) Hz frequency range
must be within the measurement
results, (These results, especially
in the pedestrian overpass ,
games and sports in the areas
of metal and absorption of sound
vibrations in the substances
is important
All
of the products mentioned above,
including reports and documents,
including experiments at least
1 of the University section of
the chemical and materials used
in heavy pedestrian traffic use
of the approved report must be
approved.
3
Year to all products by the company
seal guarantees should be corrosion-proofing
up 7 Years
1000
m2 and above all the products
and practices conducted by the
company for 9 months at least
1 time during 3 years free warranty
maintenance and renewal must
be made
All
prices of products that produce
or sell products or firms are
connected by the ITO must be
certified by the trade or industry
chambers.